APC AP7921 Rack PDU, Switched, 1U, 16A, C20 -> (8)C13 - Horizontal

AP7921731304210818APCAPC's Switched Rack Power Distribution Units (PDUs) are premium solutions to many of the power management problems seen in today's IT environments. Some of the problems are unauthorized use of power outlets, locked-up equipment, in-rush current, overloaded circuits, and the need of remote access to power outlets in the rack. The Switched Rack PDUs address these problems through individual outlet control, power on and off delays, current monitoring, alarm thresholds, and network management.
Individual outlet control allows users to turn outlets on, turn outlets off, or recycle power to equipment, which can reboot locked-up equipment and avoid unauthorized use of outlets. Power delays allow users to determine the order in which equipment is powered up or down. Utilizing the power delay feature will avoid in-rush current, which can cause overloads.
Monitoring the current draw at the rack level is key to avoiding downtime due to overloaded circuits. The Switched Rack PDUs provide an aggregate current draw, which can be viewed remotely or locally, via digital display. In addition, alarms will be generated based on user-defined thresholds to alert users of potential circuit overloads.
Users can access, configure, and control the Switched Rack PDUs through Web, SNMP, or Telnet Interfaces.


Key Features & Benefits:
" Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
" Current Monitoring: Monitors the aggregate current draw of the power distribution unit. This helps avoid overloaded circuits by warning installers and users that they are close to the maximum amperage draw of the unit.
" Current Alarm Thresholds: Users can define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
" Power on and off Delays: Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
" Remote Management Capabilities: Full-featured network management interfaces that provide standards-based management via Browser, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time.

Description: Power distribution that remotely controls power to individual outlets and monitors the aggregate power consumption
Features: 19 inch Rack-Mountable, Alarm Thresholds, Flash Upgradeable, Local Current Monitoring Display, Multiple User Support, Power Delays, Remote Current Monitoring, Remote Individual Outlet Control, Remote Management Capabilities
Includes: Installation Guide, Rack Mounting Brackets, User Manual

Output
Voltage(s) (main only): 208, 230 V
Maximum Total Current Draw per Phase: 16 A
Output Connections: (8)IEC 320 C13

Input
Nominal input voltage 208, 230
Input frequency (Hz) 50/60 Hz
Input Connection Type IEC-320 C20
Cord Length 8.2 feet ( 2.5 meters)
Maximum Input Current per phase 16 A
Load Capacity 3680

Net Weight 2.27 KG
Maximum Height 44.00 mm
Maximum Width 445.00 mm
Maximum depth 108.00 mm
Shipping Weight 3.45 KG
Shipping Height 70.00 mm
Shipping Width 470.00 mm
Shipping Depth 343.00 mm
Color Black

Ilustrativní obrázek
APC's Switched Rack Power Distribution Units (PDUs) are premium solutions to many of the power management problems seen in today's IT environments. Some of the problems are unauthorized Celý popis
Ilustrativní obrázek
ilustrační obrázek
Dostupné: Produkt se již nedodává
Chci být informován, až bude produkt dostupný.


Zaslání informace o dostupnosti zboží

Pokud chcete, abychom Vám zaslali informaci, až bude produkt opět dostupný. Klikněte na tlačítko odeslat žádost.

Informace Vám bude odeslána na e-mail:

EAN:
731304210818
Doprava po celé ČR zdarma
V ceně je zahrnut recyklační poplatek.
P/N:
AP7921
DPH:21 %
Hmotnost:3.45 kg


 
5 stars, based on 1 reviews
APC's Switched Rack Power Distribution Units (PDUs) are premium solutions to many of the power management problems seen in today's IT environments. Some of the problems are unauthorized use of power outlets, locked-up equipment, in-rush current, overloaded circuits, and the need of remote access to power outlets in the rack. The Switched Rack PDUs address these problems through individual outlet control, power on and off delays, current monitoring, alarm thresholds, and network management.
Individual outlet control allows users to turn outlets on, turn outlets off, or recycle power to equipment, which can reboot locked-up equipment and avoid unauthorized use of outlets. Power delays allow users to determine the order in which equipment is powered up or down. Utilizing the power delay feature will avoid in-rush current, which can cause overloads.
Monitoring the current draw at the rack level is key to avoiding downtime due to overloaded circuits. The Switched Rack PDUs provide an aggregate current draw, which can be viewed remotely or locally, via digital display. In addition, alarms will be generated based on user-defined thresholds to alert users of potential circuit overloads.
Users can access, configure, and control the Switched Rack PDUs through Web, SNMP, or Telnet Interfaces.

Key Features & Benefits:
" Individual Outlet Control: Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
" Current Monitoring: Monitors the aggregate current draw of the power distribution unit. This helps avoid overloaded circuits by warning installers and users that they are close to the maximum amperage draw of the unit.
" Current Alarm Thresholds: Users can define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
" Power on and off Delays: Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
" Remote Management Capabilities: Full-featured network management interfaces that provide standards-based management via Browser, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time.
Description: Power distribution that remotely controls power to individual outlets and monitors the aggregate power consumption
Features: 19 inch Rack-Mountable, Alarm Thresholds, Flash Upgradeable, Local Current Monitoring Display, Multiple User Support, Power Delays, Remote Current Monitoring, Remote Individual Outlet Control, Remote Management Capabilities
Includes: Installation Guide, Rack Mounting Brackets, User Manual
Output
Voltage(s) (main only): 208, 230 V
Maximum Total Current Draw per Phase: 16 A
Output Connections: (8)IEC 320 C13

Input
Nominal input voltage 208, 230
Input frequency (Hz) 50/60 Hz
Input Connection Type IEC-320 C20
Cord Length 8.2 feet ( 2.5 meters)
Maximum Input Current per phase 16 A
Load Capacity 3680
Net Weight 2.27 KG
Maximum Height 44.00 mm
Maximum Width 445.00 mm
Maximum depth 108.00 mm
Shipping Weight 3.45 KG
Shipping Height 70.00 mm
Shipping Width 470.00 mm
Shipping Depth 343.00 mm
Color Black


Chcete se o produktu dozvědět více? Napište nám

E-mail: Váš e-mail pro odpověď
Text:


NázevHodnota
Rozsah teplot při skladování (T-T)-25 - 65 °C
Depth:475 mm
Provozní rozsah teplot (T-T)0 - 45 °C
Width:340 mm
Height:70 mm
Net weight:3.733 kg
Délka kabelu2.5 m
Provozní nadmořská výška0 - 3000 m
Rozměry (ŠxHxV)444.5 x 108 x 43.9 mm
Rozsah relativní vlhkosti při skladování (H-H)0 - 95 %
Doporučená provozní relativní vlhkost0 - 95 %
BarvaČerná
Jak zákazníci hodnotí produkt

APC AP7921 Rack PDU, Switched, 1U, 16A, C20 -> (8)C13 - Horizontal

Průměrné hodnocení 100%. Hodnotil 1 zákazník. Zobrazujeme pouze hodnocení s vyplněným textem.

uvozovkyOKuvozovky

před 8 měsíci, Anonym   
KUPTE TOTO ZBOŽÍ DNES A ZAPLAŤTE JEJ AŽ PO VYZKOUŠENÍ.

KUP NAJISTO - Nová platební služba pro jistotu při nakupování.

Vyzkoušejte vaše zboží doma, zaplaťte za 14 dní.

Pro schválení služby Kup Najisto budete přesměrováni na stránky pro ověření Vaší identity. Podle výše Vašeho nákupu můžeme k ověření Vaší identity požadovat i rodné číslo, případně číslo občanského průkazu.

Údaje zpracováváme zabezpečeně a v souladu se Zákonem o ochraně osobních údajů.
Platební služba Kup Najisto není určena pro podnikatele a firmy (držitelé IČ).

 
 

Rodina NWT

Nákup bez obav

Patro.cz

Rychlý kontakt

Tento web používá k poskytování služeb, personalizaci reklam a analýze návštěvnosti soubory cookie. Používáním tohoto webu s tím souhlasíte.
Podle zákona o evidenci tržeb je prodávající povinen vystavit kupujícímu účtenku. Zároveň je povinen zaevidovat přijatou tržbu u správce daně online; v případě technického výpadku pak nejpozději do 48 hodin.